SPCC Plan Requirements For Containers And Tanks

Are non-transportation related.
– Have an aggregate above ground storage capacity greater than 1,320 gallons (including all tanks, containers, and operating equipment 55 gallons or greater in capacity) or a totally buried storage capacity greater than 42,000 gallons.
– Have a geographic location where there may be a reasonable expectation of a discharge into or upon navigable waters of the US or adjoining shorelines.

Definition of Oil
Facilities that meet these three conditions must include bulk storage containers used to store oil in their SPCC Plan, if these containers have a capacity of 55 gallons or more. Oil is defined as:
Petroleum products, including gasoline, diesel, and engine oil
– Animal fats
– Vegetable oils

Generally, a plan is required for any non-transportation related onshore and off- shore facility that’s engaged in drilling, producing, storing, gathering, processing, transferring, distributing, using, or consuming oil products.

When Can a Container Be Excluded Out of your SPCC Plan
A bulk storage container used to sj petroleum machinery store oil that has a capacity of 55 gallons or greater may not require inclusion in the installation’s SPCC Plan only under the next conditions:
– The container is a part of a separate facility that will need to have a separate SPCC Plan.
– The container is a part of a separate facility that doesn’t have to prepare an SPCC Plan (a facility that doesn’t meet the required criteria).

reaction kettleRequirements for a Diagram
There are various specific requirements outlined in 40 CFR 112 regarding your facility’s Spill Prevention, Control, and Countermeasure Plan. In line with ยง112.7 (a)(3),
a facility diagram should sj petroleum machinery be included and clearly outline:
– Location of oil containers.
– Type of oil in each container.
– Location of any completely buried storage tanks which might be otherwise exempted from SPCC regulations.
– Location of transfer stations and piping.
– Locations where mobile or portable containers are stored.

The SPCC Plan must include the storage capacity of every container but this does not have to be on the diagram.

Drawings and Photographs within the SPCC Plan
Site specific diagrams will not be required if the power diagram is explicit and complete. It must include:
– The direction of oil flow.
– The speed of flow.
– The entire quantity of oil that could possibly be discharged as a result of each type of major equipment failure. This may occasionally include loading/unloading equipment, tank rupture, overflow or leakage.

If site specific drawings or detailed facility drawings are included, illustrate:
– The predicted discharge direction on the drawing.
– Discuss the speed of flow and quantity of oil that could be discharged because of the several types of equipment failure.

Photographs should not required but they may assist in rapid recognition of the positioning sj petroleum machinery layout. They’ll illustrate a visual history of the physical condition of the ability and/or the containers located there.